The ATE 1-ind is highly compact (40x20x07mm) and lightweight (10g). It includes the conditioning for type K thermocouples or stress gauges. Data is transmitted using frequency modulation (PCM) or inductive loop. It is battery (3.6V) or induction powered. Data is retrieved as analogue output or in CAN2B or USB2 format. The applications are multiple (distorsion or temperature measurement on transmission shafts, rotating machinery, in the automotive, aeronautical or industrial sectors).
Request a quotebattery powered, lithium battery powered or self powered by induction
maximum temperature -40°C + 125°C (-20°C +85 °C for battery powered) 210 °C bespoke high temperature measurement option
maximum acceleration 10,000G (40,000 G option)
bandwidth up to 100 000 ech/s
size: 40X20X07 mm
gain and offset programmable by USB 2 ( soft PC ) or remotely using radio transmission
digital PCM radio transmission
IP65 anodised aluminium case
radio receiver output 0-5V analogue and USB 2 (CAN2B option available)
There is also a bespoke broadband, high temperature (+200°C) line for all specific applications.